¤ WNY Series
  • Performance parameters
  • Diagram
  • Wiring instructions
  • Corresponding accessories
  • Operation video
  • Attentions

●Characteristics:

1.This kind of pump has dual function that can be used for liquid or gas sampling.It is a self-priming pump.
(When turned on ,the pump starts to do the liquid sampling,no extra water is needed at the beginning.)
It also allows dry running.(When the liquid runs out or without liquid ,the pump can run smoothly without any damage)
It is equipped with brushless DC motor, durable and low interference.It can run continuously around the clock without 
interfering with the surrounding electronic components or polluting power source. Stable performance and high reliability. 
Maintenance-free .Damp gas as the medium is acceptable. No pollution during the gas transmitted as it is oilless operation. 
Corrosive gas is allowed to be input(The material for the parts which come in contact with gas : Glass fiber reinforced 
nylon ,EPDM rubber, silicon rubber)

2.Easy to adjust the speed of the pump.The flow rate can be changed by freely adjusting the rotate speed of motor through
electrical control.There are feedback signals about the rotating speed of motor, which indicate the working status and 
can realize closed-loop control,thus facilitate the intelligent control.(this function do not apply to Economical version
and Simplified version)

3.It can be mounted in any plane.such as horizontal plane,vertical plane, slope.Perfect self-protective function.
It has functions of overheating protection and overload protection.(This function do not apply to Economical version)
The pump applies to wide fields, especially in gas (or liquid) analyzer, industrial instruments etc.

 

 ●Certificate:

CE

CONFORMITE

 EUROPEENNE

EMC

Electro      Magnetic  

 Compatibility

 

 ●Technical Specifications

Model

As the vacuum pump

As the liquid pump

Operating

 Voltage

Load

 Current

Flow rate

(effective value)

Vacuum

(negative pressure)

Operating 

Voltage

Load 

Current

Flow rate

(effective value)

V DC

mA

L/min

kPa

V DC

mA

L/min

WNY600

12±10%

<330

0.6

≈ -17

12

<350

0.6

24±5%

<200

0.8

24

<260

WNY1000

12±10%

<380

0.9

≈ -27

12

<500

1.0

24±5%

<220

1.1

24

<280

Remark : customized is available

 

●Testing of Water Suction and Discharge Height

1.All the connective hose is flexible rubber hose(Inner diameter approximately 5mm)

2.The liquid suction is clean water.

3.The definition for Max.suction height H1 and max.drainage height H2 as follow:

4.The data may be updated in future without any notice.

Model

Max.suction
height H1 (m)

Flow rate at Max.suction height
(mL/min)

Max.drainage 
height H2(m)
Flow rate at Max. 
drainage height
(mL/min)

WNY600

2

>300

4

>280

WNY1000

3

>400

5

>280

 

Remark : 
To test the H1 ,The length for drain-hose is <100mm .
To test the H2 ,The length for suction-hose is <100mm.

 

 ●Performance Comparison:

       Version

Economical version

Simplified version 

Standard version

Component 

(quality level)

Brushless motor

★★

★★★★

Diaphragm

★★

★★★★

Bearing

★★

★★★★

Performance

 

Continuous loading service life

service life as vacuum pump >3000 hours
service life as liquid pump >2500 hours
service life as vacuum pump >6000 hours
service life a s vacuum pump >5000 hours
service life as vacuum pump >12000 hours
service life as vacuum pump >8000 hours
Electromagnetic Interference

▲▲▲▲

▲▲▲

Ambient Temperature

0~40℃

0~50℃

0~50℃

Adjustment of speed

overload protection

×

Overheating protection

×

Speed feedback Signal

×

×

Frequently start-stop parameters

Service life

>180 thousand times

>800 thousand  times

>1.8 million times

Working condition for test

Run 30 seconds,
Stop 30 seconds

Run 15 seconds,
Stop 15 seconds
Run 10 seconds,
Stop 10 seconds
Cycle operation around the clock,the inlet is blocked completely.Test is still undergoing

Speeder matched

Only match with simplified version speeder
 
steady speed type speeder,digital speeder,simplified speede

 

Remarks:
1.The more ★ is,the better performance of this pump shall be.
The fewer ▲ is the lower electromagnetic interference of this pump shallbe.

2.The above comparison does not mean a product is not good.
It is for customers reference only. Here by Instructions!

Tips for service life test: 

1.Test condition: The service life test results based on clean & non-corrosive laboratory,
the pumps run continuously around the clock with full load. If the operation condition is 
better than that of our, service life will be greatly extended.
Laboratory conditions:

Ambient temperature: 5℃-33℃, fluctuates according to the climate
Relative humidity: 50%-85%, fluctuates according to the climate

2.Instructions for Loading Test:When the inlet completely been blocked, gas outlet through
to the atmosphere without any connection. 

3.Because the test is undergoing checking, the data may be updated in future without any notice.

 

●Attentions:

1.To be used as gas pump,both the inlet and outlet of this pump can run 
in heavy duty ,even completely blocked, both are proper functioning.

2.To be used as liquid pump, the inlet of this pump can run in heavy-duty,
even completely blocked. The outlet should remain unobstructed.

3.Customization is available.

4.Weight: approximately 310 g.

5.All parameters presented in this instruction are based on the standard 
atmospheric pressure at 25℃, unless otherwise defined. The free flow is 
referred to as the flow.

 

●User Instructions

1.Service Conditions

The pump shall not be exposed to direct sun light.
It shall work in clean and non-corrosive environment.
Ambient temperature: 
Economical version: 0-40 ℃ (No condensation) 
Simplified version & standard version:0-50 ℃ (No condensation)
Relative humidity: ≤ 90 %

2.Working medium

Gas or liquid is allowed, but with solid particles are not acceptable.
The materials and names for the parts which come in contact with gas 
(or liquid) as below:

Part name

Part material

Remark

pump body

Glass fiber reinforced nylon

All material has certain ability of corrosion resistance, please evaluate the tolerance of the parts which come in contact with gas pumped.

diaphragm

EPDM rubber

valve

Silicone rubber

 

According to the temperature of gas inlet,the series product can be divided into two types,
normal-temperature medium type and high-temperature medium type.Orders for high-temperature 
medium type shall be specifically marked, otherwise, it shall be normal-temperature medium type.

Type

Temperature range allowed for gas suction

Remark

Normal-temperature medium type

0~50℃

Solid particles such as ice particles are forbidden to be contained in the gas suction.

High-temperature medium type
0~100℃

WNY Series Dimensional Drawings

UG

Drawing unit: mm

 

●Wiring instructions:

Item

Color of leading wire

Function

Action voltage

Remark

1

White

 

Control the start & stop of motor(optional wire)

 

2V≤star ≤5V

0V≤stop≤0.8V

This wire is used for the control the star and stop of pump.Especially frequent starts and stops.If you do not need ,should wrap it with insulation material .Disconnect this red power wire ,if the pump do not work for a long time.

2

Blue

Pulse Width Modulation(PWM)

 

 

0V≤star ≤0.8V 

2V≤stop≤5V

Adjust the motor speed and pump flow by changing the duty-cycle.We suggest the PWM input signal frequency in this range :20KHz-30KHz .This port can not control the start & stop.

 

3

Yellow

 

FG feedback signal (motor speed feedback signal, pulse signal).The motor output 6 pulse for making a circle (No yellow wire for economic version and simplified version).

Low level <0.5V;high level <6V,recommend high level=5V.Max.rated current of FG signal is 2mA .   

The internal motor is open-drain status,therefore you need to be pulled outside.Voltage 5V,resistance 5.1kΩ.

4

Orange

 

Special wire ,no useful for this pump
Connect with positive pole

 

5

Black

 

Power wire,negative pole

 

 

6

Red

 


Power wire,Positive pole

 

 

 

 

Warning:No hot plugging!No connect or disconnect the motor leading wire when the power is on
Forbid to reverse the positive and negative pole ,otherwise the motor will be damaged!

 

If you do not need use the speed governing and speed feedback signal,connection as below:

Color of motor leading wire

Connection

Remark

Red

Positive pole

If the leading you received is yellow & white,and you do not need them,please wrap them with insulation material separately.

White

Negative pole

Orange

Black

 

 

●Motor electrical schematic diagram and peripheral circuit:

 

1.As shown in figure. Several ports must connect schottky diode, here is why:
the internal functions of the motor control and drive are MOS(Metal-Oxide-Semiconductor) tube,
the input impedance is high, the ports must be connected to the schottky diodes to prevent
any accidental larger jamming signal to breakdown the MOS tube.

2.The requirement for the control of electricity level: 0V≤low level≤0.8V,2V≤high level≤5V

3.FG port for motor speed feedback signal, should be paid attention to in the application:
FG output signal port is open drain, the user needs to connect a pull-up resistors,
an application example as shown in figure.

 

 

 

 Optional Accessories

Filter Silicone tube(Note: inner diameter is about 5mm, and outer diameter is about 9mm.)

 

  Note: A medium size filter and a 10cm silicone tube will be included in the package for each
pump.

 

  Attentions

      1.The water outlet of the pump must be unobstructed. No foreign substance is allowed in the nozzle, or the micro pump may be damaged.

      2.The product is not intrinsically safe. It is not recommended to be used in inflammable and explosive environment!

      3.When the air pumped is hazardous, users must re-seal the pump for the sake of safety!

Chengdu Qihai Electromechanical Equipment Manufacturing Co., Ltd
成都气海机电制造有限公司 蜀ICP备12008449 成公网备字[200600057]号