¤ KAB Series
  • Performance parameters
  • Diagram
  • Wiring instructions
  • Corresponding accessories
  • Operation video
  • Attentions

Characteristics:

1.Integrated speed adjustment function,flow regulation is very convenient.Two speed adjustment function type,
good expansible.One,use the built-in speeder.Another one,adjust the speed with the external potentiometer

2.The function of integrated speed indicator,according to the flash frequency of the indicator to understand
the operation of the pump intuitively.Perfect self-protective function.It has functions of overheating protection
and overload protection.

3.It is equipped with brushless DC motor,durable and low interference.It can run continuously around the clock without
interfering with the surrounding electronic components or polluting power source.Stable performance and high reliability.
Maintenance-free.Damp gas as the medium is acceptable.No pollution during the gas transmitted as it is oilless operation. 
Corrosive gas is allowed to be input(The material for the parts which come in contact with gas:SPS(Syndiotactic polystyrene 
resin,EPDM rubber)

 

Technical specification:

Model

Rated voltage
Working voltage range

Loaded current

The average flow adjustable range

Vacuum value
(Gauge pressure) 

(V DC)

(V DC)

(mA) 

(L/min)

MAX. value

MIN.value

(kPa) 

KAB3202

24

16~28

<140

2

1.3

>32

KAB3702

12

5~13

<240

2

1.3

>37

KAB3602

5

3.3~12

<750

2

1.3

>36

Pump with other specification can be customized.

 

Performance compare:

    Item

Economical version
Standard version

Component 

(quality level)

Motor

Brushless motor
★★★
Brushless motor
★★★★

Diaphragm

★★★

★★★★

Bearing
★★★
★★★★

Performance

Continuous loading service life
≥2500 hours
>4000 hours
Test is still undergoing
Electromagnetic Interference

▲▲

Ambient Temperature

0~40℃

0~50℃

Adjustment of speed

Speed feedback Signal

Self-protective function

Remarks:
1.The more ★ is,the better performance of this pump shall be.The fewer ▲ is,
the lower electromagnetic interference of this pump shall be.
2.The above comparison does not mean a product is not good.It is for customers reference 
only.Here by Instructions!

 

Tips for service life test:

1.Test condition: The service life test results based on clean & non-corrosive laboratory ,
the pumps run continuously around the clock with full load. If the operation condition is 
better than that of our, service life will be greatly extended.

Laboratory conditions:
Ambient temperature: 5℃-33℃,fluctuates according to the climate
Relative humidity: 50%-85%, fluctuates according to the climate

2.Instructions for Loading Test:
When the inlet completely been blocked, gas outlet through to the atmosphere without any connection. 
3.Because the test is undergoing checking, the data may be updated in future without any notice.

 

Tips for selection of products:

1.The inlet of this pump can run in heavy duty,even completely blocked,both are proper functioning.

2.The outlet of this pump should remain unobstructed.If not,as the result of the blockage,
the high-pressure will be caused and threat to safety.If you need large damping components for the 
outlet, please select the FML or FAY、FKY、FCY serials.

3.Weight: approximately 100 g.

4.All parameters presented in this instruction are based on the standard atmospheric pressure at 25℃,
unless otherwise defined. The free flow is referred to as the flow.

 

User Instructions:

1.Service Conditions
The pump shall not be exposed to direct sun light.It shall work in clean and non-corrosive environment.
Ambient temperature:0-40 ℃(No condensation)
Relative humidity:≤ 90 %

2.Working medium
Solid particles are forbidden to be contained in the gas suction,but damp gas is allowed.The material 
for the parts which come in contact with gas : Syndiotactic polystyrene resin ,EPDM rubber,the two material
have certain ability of corrosion resistance ,please evaluate the tolerance of the parts which come in
contact with gas pumped.

 

KAB Series Function integrated pump Dimensional Drawings

UG

Drawing unit: mm

 

 

Instruction for Connection

Item

The color of leading wire

Function

Remark

1

Red wire

Power wire,Positive  pole

Voltage is required at ±0.5V,If reverse the negative pole and positive pole ,the motor will not be damaged ,but the pump can not able to work

2

Black wire

Power wire,Negative pole

 Optional Accessories

Filter Silicone tube(Note: inner diameter is about 3mm, and outer diameter is about 5mm.)

      Note: A small size filter and a 10cm silicone tube will be included in the package for each pump.

Attentions

     1.No foreign matter should keeping in the nozzle, or the micro pump may be damaged.

     2.The product has not explosive-proof performance. To ban the use in inflammable and explosive environment.

     3.When the gas input is hazardous, users must re-seal the pump for the sake of safety!

     4.All gas circuit elements such as gas tank must be provided with enough strength for the sake of safety.

 